{"id":8457,"date":"2019-11-14T11:53:17","date_gmt":"2019-11-14T10:53:17","guid":{"rendered":"https:\/\/www.tykoflex.se\/kapslingsklassning\/"},"modified":"2020-09-07T14:25:52","modified_gmt":"2020-09-07T12:25:52","slug":"ip-rating-ip69k","status":"publish","type":"page","link":"https:\/\/www.tykoflex.se\/en\/ip-rating-ip69k\/","title":{"rendered":"IP rating \u2013 IP69K"},"content":{"rendered":"<h2><b>Useful information about IP<br \/>\n<\/b><b>(International Protection)<\/b><\/h2>\n<p>IP ratings: IP is an enclosure rating that tells you how good an encapsulation is and how well it resists and protects against dust and water ingress. The letters IP (International Protection) are followed by two digits describing the equipment protection level. The first digit of the IP code indicates the degree to which a person is protected against contact with moving parts (other than smooth rotating shafts, etc.) and the degree to which the equipment is protected against solid foreign bodies intruding into an enclosure. The second digit indicates the degree of protection for the equipment inside the enclosure against the harmful entry of various forms of moisture (e.g. drips, spray, submersion, etc.)<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-8846 size-standard-size\" src=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP-Ratings-first-digit-660x420.jpg\" alt=\"\" width=\"660\" height=\"420\" srcset=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP-Ratings-first-digit-660x420.jpg 660w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP-Ratings-first-digit-300x191.jpg 300w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP-Ratings-first-digit-768x488.jpg 768w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP-Ratings-first-digit-1024x651.jpg 1024w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP-Ratings-first-digit-150x95.jpg 150w\" sizes=\"(max-width: 660px) 100vw, 660px\" \/><\/p>\n<h3>Test procedure<\/h3>\n<ul>\n<li>Protected against close-range high pressure, high temperature spraying<\/li>\n<li>Test duration: 30 seconds from 7 angles (3 minutes total)<\/li>\n<li>Pressure: 10 MPa (100 bar)<\/li>\n<li>At a distance of 0.125 m<\/li>\n<li>Water temperature: 80 \u00b0C<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"alignnone size-large wp-image-4470\" src=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Skravboxar-1024x683.jpg\" alt=\"\" width=\"1024\" height=\"683\" srcset=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Skravboxar-1024x683.jpg 1024w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Skravboxar-300x200.jpg 300w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Skravboxar-768x512.jpg 768w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Skravboxar-150x100.jpg 150w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Skravboxar-660x440.jpg 660w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>Closure\u00b4s tested with all variants of bushing technology for the Telecombox T240 system.<\/p>\n<h3><b>Classification of the degree of protection provided by the enclosure<\/b><\/h3>\n<h4>Standard<\/h4>\n<p>EN 60529:1991 + A1:2000 + A2:2013<br \/>\nIEC 60529:1989 + A1:1999 + A2:2013<br \/>\nISO 20653:2013<\/p>\n<h4>IP-class<\/h4>\n<p>IP68 (2.0 bar\/24 h)\/IP69, IP69K<\/p>\n<h3><img decoding=\"async\" class=\"wp-image-4480 size-medium alignright\" src=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/HighPressure_spray_IP69K-241x300.jpg\" alt=\"\" width=\"241\" height=\"300\" srcset=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/HighPressure_spray_IP69K-241x300.jpg 241w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/HighPressure_spray_IP69K-768x955.jpg 768w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/HighPressure_spray_IP69K-824x1024.jpg 824w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/HighPressure_spray_IP69K-121x150.jpg 121w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/HighPressure_spray_IP69K-354x440.jpg 354w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/HighPressure_spray_IP69K.jpg 2000w\" sizes=\"(max-width: 241px) 100vw, 241px\" \/><b>Technical description<\/b><\/h3>\n<ul>\n<li>The largest dimension of the Telecombox T240 exceeds 250 mm and the test was therefore performed with the test parameters for large enclosures.<\/li>\n<li>The test objects were exposed to high-pressure water from all directions for a total of 3 minutes.<\/li>\n<li>The water pressure was approximately 100 bar and the spraying distance was 125 mm.<\/li>\n<li>The temperature of the water was 80\u00ba C.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><img decoding=\"async\" class=\"alignright wp-image-4471 size-medium\" src=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Trycktest-300x200.jpg\" alt=\"Testobjekt i trycktank f\u00f6r IP68 test med 2 bar tryck.\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Trycktest-300x200.jpg 300w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Trycktest-768x512.jpg 768w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Trycktest-1024x683.jpg 1024w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Trycktest-150x100.jpg 150w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Trycktest-660x440.jpg 660w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><b>Test equipment<\/b><\/h3>\n<p><b>High-pressure washer:<span class=\"Apple-converted-space\">\u00a0<\/span><\/b> KEW 52C3KA<br \/>\n<b>Nozzle:<\/b><span class=\"Apple-converted-space\">\u00a0 <\/span>RISE inventory no. BX41793<br \/>\n<b>Sliding calliper: <span class=\"Apple-converted-space\">\u00a0<\/span><\/b> RISE inventory no. 501806<br \/>\n<b>Water flow meter:<span class=\"Apple-converted-space\">\u00a0<\/span><\/b> RISE inventory no. 501880<br \/>\n<b>Frequency counter:<span class=\"Apple-converted-space\">\u00a0<\/span><\/b> RISE inventory no. 503436<br \/>\n<b>Thermometer:<span class=\"Apple-converted-space\">\u00a0<\/span><\/b> RISE inventory no. BX41792<br \/>\n<b>Stopwatch:<\/b><span class=\"Apple-converted-space\">\u00a0 <\/span>RISE inventory no. 501336<\/p>\n<p><b>Measuring tolerances<\/b><\/p>\n<p><b>Spraying distance:<span class=\"Apple-converted-space\">\u00a0<\/span><\/b> \u00b1 25 mm<br \/>\n<b>Water temperature:<\/b><span class=\"Apple-converted-space\">\u00a0 <\/span>\u00b1 5 \u00b0C<br \/>\n<b>Time:<span class=\"Apple-converted-space\">\u00a0 <\/span><\/b> \u00b1 3.5 s<\/p>\n<p><img decoding=\"async\" class=\"alignleft wp-image-4467 size-medium\" src=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest1-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest1-300x200.jpg 300w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest1-768x512.jpg 768w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest1-1024x683.jpg 1024w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest1-150x100.jpg 150w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest1-660x440.jpg 660w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> <img decoding=\"async\" class=\"alignnone size-medium wp-image-4468\" src=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest2-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest2-300x200.jpg 300w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest2-768x512.jpg 768w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest2-1024x683.jpg 1024w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest2-150x100.jpg 150w, https:\/\/www.tykoflex.se\/wp-content\/uploads\/IP69K_Dammtest2-660x440.jpg 660w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><br \/>\nClosures set-up for an IP6X dust test with vacuum pump connection.<\/p>\n<hr \/>\n<h3>Tykoflex testing<\/h3>\n<p>At Tykoflex we of course conduct our own tests both outdoors and in our climate chamber, here is an example.<\/p>\n<style>.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }<\/style>\n<div class=\"embed-container\"><iframe src=\"https:\/\/www.youtube.com\/embed\/\/h17jP_bdcaU\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Useful information about IP (International Protection) IP ratings: IP is an enclosure rating that tells you how good an encapsulation is and how well it resists and protects against dust and water ingress. The letters IP (International Protection) are followed&#8230;<\/p>\n","protected":false},"author":12,"featured_media":0,"parent":0,"menu_order":8,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-8457","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.tykoflex.se\/en\/wp-json\/wp\/v2\/pages\/8457","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tykoflex.se\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.tykoflex.se\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.tykoflex.se\/en\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tykoflex.se\/en\/wp-json\/wp\/v2\/comments?post=8457"}],"version-history":[{"count":5,"href":"https:\/\/www.tykoflex.se\/en\/wp-json\/wp\/v2\/pages\/8457\/revisions"}],"predecessor-version":[{"id":9857,"href":"https:\/\/www.tykoflex.se\/en\/wp-json\/wp\/v2\/pages\/8457\/revisions\/9857"}],"wp:attachment":[{"href":"https:\/\/www.tykoflex.se\/en\/wp-json\/wp\/v2\/media?parent=8457"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}